試驗方式/適用規范 | IEC61215 | L1703 |
電氣特能測試(Electrical performance test) | ● | ● |
熱循環測試(Thermal cycle test) | ● | ● |
濕冷凍循環測試(Humidity freeze cycle test) | ● | ● |
機械負荷測試(Mechanical load test) | ● | ● |
熱班耐受測試(Hot-spot endurance test) | ● | ● |
目視檢查(Visual inspection procedure) | ● | |
電氣絕緣測試(Electrical isolation test [dry hi-po]) | ● | |
旁路二極管熱測試(Bypass diode thermal test) | ● | |
濕漏電流測試(Wet leakage current test) | ● | |
冰雹沖擊測試(Hail impact test) | ● | |
濕熱測試(Damp heat test) | ● | |
連接端穩定測試(Robustness of terminations test) | ● | |
戶外曝曬測試(Outdoor exposure test) | ● | |
紫外線前處理測試(V Preconditioning Test) | ● | |
溫度系數量測(Measurement of temperature coefficients) | ● | |
標稱工作[NOCT]溫度的量測(Measurement of nominal operating cell temperature) | ● | |
在低照射光下的性能(Performance at low irradiance) | ● | |
標稱工作溫度[NOCT]下性能(Performance at NOCT) | ● | |
*大功率測定(Maximum power determination) | ● | |
接合路徑電阻測試(Bonding path resistance test) | | ● |
濕隔離電阻測試(Wet insulation resistance test) | | ● |
耐電壓測試(Dielectric voltage-withstand test) | | ● |
電弧試驗(Arcing test) | | ● |
泄漏電流測試(Leakage current test) | | ● |
潑水測試(Water spray test) | | ● |
高溫測試(Temperature test) | | ● |
加速老化測試(Accelerated aging test) | | ● |
線扣拉力測試(Strain relief test) | | ● |
反向電流超載試驗(Reverse current overload test) | | ● |
端子扭矩測試(Terminal torque test) | | ● |
推擠測試(Push test) | | ● |
切割測試(Cut test) | | ● |
沖擊測試(Impact test) | | ● |
防火測試(Fire test) | | ● |
氣體腐蝕測試(Corrosive atmosphere test) | | ● |
金屬涂層厚度試驗(Metallic coating thickness test) | | ● |
布線穩定性測試(Wiring Compartment Securement Test) | | ● |
試驗總數 | 共19項 | 共23項 |